ACI 318 / IS 456 / EC2

Footing Size Calculator

Minimum square isolated footing plan dimensions from column service load and allowable soil bearing capacity. Use this as a quick first estimate before running the full design.

Total unfactored (service) column axial load including self-weight of footing

Net allowable bearing pressure from the geotechnical report

Get the full footing design — punching shear check, flexural reinforcement, BBS, and PDF report.

Open Civora App →

How to Size an Isolated Footing

The footing plan area is sized from the service (unfactored) loads against the allowable bearing pressure from the geotechnical report. Factored loads are used only for flexural and shear design — not for sizing the plan dimensions.

Formula

A_required = P_service / q_allow
B = √A_required    (square footing side)

Where P_service includes the column load, the footing self-weight, and the soil overburden above the footing. A common approximation is to take footing self-weight as 5–10% of the column load.

After Sizing

Once the plan dimensions are set, you need to check: